Vapor coolers

Steam coolers are designed for efficient and reliable steam temperature reduction in various industrial applications. Thanks to advanced engineering, they provide high performance and a long service life even in demanding conditions.

CHP

Parameters

Nominal brightness DN200÷DN700 Nominal pressure PN16÷PN160 Maximum temperature [°C] 610 Connection Welding / Flanged Standard ČSN, EN (connection also according to ANSI, GOST) Body material P245GH, 16Mo3, 13CrMo4-5, 10CrMo9-10, X10CrMoVNn9-1 Principle of cooling Using atomizing steam Functional range 3%÷100% of nominal flow Minimum steam temperature after cooling Saturation temperature + 7-11°C Minimum △p of injection water and cooled steam [bar] 3 Use Reduction and cooling stations, Turbine extraction, Turbine back pressure, Large flow ranges of steam and cooling water

PRCH

Parameters

Nominal brightness DN250÷DN500 Nominal pressure PN16÷PN100 Maximum temperature [°C] 550 Connection Welding / Flanged Standard ČSN, EN (připojení i dle ANSI, GOST) Body material P245GH, 16Mo3, 13CrMo4-5, 10CrMo9-10 Principle of cooling Aerodynamic Functional range 15%÷100% of nominal flow Minimum steam temperature after cooling Saturation temperature + 7-11°C Minimum △p of injection water and cooled steam [bar] 1 Use Reduction and cooling stations, Bypass stations, Steam for technological processes

TCH-RT

Parameters

Nominal brightness DN125÷DN1400 Nominal pressure PN16÷PN160 Maximum temperature [°C] 610 Connection Welding / Flanged Standard ČSN, EN (connection also according to ANSI, GOST) Body material P245GH, 16Mo3, 13CrMo4-5, 10CrMo9-10, X10CrMoVNn9-1 Principle of cooling Spraying with nozzles Functional range 3%÷100% of nominal flow Minimum steam temperature after cooling Saturation temperature + 7-11°C Minimum △p of injection water and cooled steam [bar] 5 Use Reduction and bypass stations, Back pressure turbines where there is a requirement for low pressure losses, Extraction steam from turbines

VCHA

Parameters

Nominal brightness DN100÷DN700 Nominal pressure PN16÷PN400 Maximum temperature [°C] 610 Connection Welding / Flanged Standard ČSN, EN (connection also according to ANSI, GOST) Body material P245GH, 16Mo3, 13CrMo4-5, 10CrMo9-10, X10CrMoVNn9-1 Principle of cooling Aerodynamic Functional range 10%÷100% of nominal flow Minimum steam temperature after cooling Saturation temperature + 7-11°C Minimum △p of injection water and cooled steam [bar] 2 Use Reduction and cooling stations, Bypass stations, Steam boiler (superheaters, intermediate superheaters)

VCHT

Parameters

Nominal brightness DN25÷DN200 Nominal pressure PN16÷PN400 Maximum temperature [°C] 550 Connection Welding / Flanged Standard ČSN, EN (connection also according to ANSI, GOST) Body material P245GH, 16Mo3, 13CrMo4-5, 10CrMo9-10, X10CrMoVNn9-1 Principle of cooling Aerodynamic Functional range 15%÷100% of nominal flow Minimum steam temperature after cooling Saturation temperature + 7-11°C Minimum △p of injection water and cooled steam [bar] 0.7 Use Reduction and cooling stations, Bypass stations, Packing steam, Steam for technological processes
We use cookies for basic and advanced functions that make it easier for you to browse the website. They also help us optimize the site and advertising campaigns to make them as beneficial as possible for all users. Click the "I agree" button allow all cookies or you can allow technical only or set your preferences. You can change all preference settings at any time in the future using the button in the lower left corner of the page.

The use of functional cookies is necessary for the proper functioning of the website and all functions. They serve only the technical purposes of the site and no third party has access to their content. Functional cookies enable e.g. searching, filtering, shopping, logging in or saving cookie preference settings. For the reasons stated, it is not possible to deactivate these cookies and they must always be enabled.

Analytical cookies provide information used for analytical and statistical purposes by the website operator and possibly third-party tools used for these purposes. This is, for example, the measurement of traffic, performance and usability of the website, advertising campaigns, etc. Thanks to the data obtained from these cookies, we can optimize the performance and functionality of the website. Information obtained with the help of these cookies is processed in aggregate and completely anonymously, without the possibility of identifying a specific user.

Marketing cookies are usually used by our partners to set up and optimize relevant content in their partner advertising network. All available data is so-called pseudo-anonymized, and as a result identification of a specific user is usually not possible. By giving consent to the use of these marketing cookies, you will see content and information relevant to your interests in advertising campaigns.

Cookie settings